广告招募

当前位置:中非贸易网 > 技术中心 > 所有分类

美国2B臭氧检测仪 106系列参数对比

2026年08月06日 18:23:09      来源:北京同林科技有限公司 >> 进入该公司展台      阅读量:2

分享:

美国2B臭氧检测仪 106系列参数对比

美国2B 106系列包括 106-L,M,MH,H,哪种臭氧监测仪适合您呢?使用这个全面的 2B Tech 106臭氧监测仪比较表,确定很适合您应用的臭氧监测仪。下表比较了各种 2B Tech 106臭氧监测仪的规格,旨在帮助确定哪种臭氧监测仪很适合您的应用。
 
SpecificationModel
106-L​106-M106-MH106-H
Measurement PrincipleUV AbsorbanceUV AbsorbanceUV AbsorbanceUV Absorbance
Dual Beam?NoNoNoNo
Federal Equivalent Method (FEM)YesN/AN/AN/A
Linear Dynamic Range0-100 ppm0-1000 ppm0-10,000 ppm0-20 wt%
Resolution0.1 ppb0.01 ppm0.1 ppm0.01 wt%
Precision (1σ for 10-s average; aka rms noise)1.5 ppb or
2% of Reading
0.01 ppm or
2% of Reading
0.05 ppm or
2% of Reading
0.01 wt% or
2% of Reading
Accuracy1.5 ppb or
2% of Reading
0.01 ppm or
2% of Reading
0.05 ppm or
2% of Reading
0.01 wt% or
2% of Reading
CalibrationNIST TraceableNIST TraceableNIST TraceableIodometric Titration
Limit of Detection (10-s measurement, 2σ)3.0 ppb0.02 ppm0.10 ppm0.02 wt%
Flow Rate (nominal)1 L/min1 L/min1 L/minUp to 20 L/min
Flow Rate Requirement>0.6 L/min>0.3 L/min>0.2 L/min>0.5 L/min
Baseline Drift<3 ppb/day
<6 ppb/year
<0.01 ppm/day
<0.03 ppm/year
<0.1ppm/day
<0.3ppm/year
<0.02%/day
<0.05%/month
Sensitivity Drift<1%/day
<3%/year
<1%/day
<3%/year
<1%/day
<3%/year
<1%/day
<3%/year
Measurement Time, Frequency2 s, 0.5 Hz2 s, 0.5 Hz2 s, 0.5 Hz2 s, 0.5 Hz
Response Time, 99% of Step Change4 s
2 points
4 s
2 points
4 s
2 points
4 s
2 points
Averaging Times10 s,
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
10 s,
1 min, 5 min,
1 hr
Ozone Unitsppb, pphm, ppm, µg m-3,
mg m-3
ppb, pphm, ppm, µg m-3,
mg m-3
ppm, mg m-3vol %, wt % air,
wt % O2, g m-3,
g Nm-3
Pressure Unitsmbar, torrmbar, torrmbar, torrmbar, psi, torr
Temperature Units°C, K°C, K°C, K°C,°F, K
T and P CorrectedYesYesYesYes
Operating Temperature Range0 to 50 °C0 to 50 °C0 to 50 °C0 to 50 °C
Operating Altitude~0-13.5 km (0-25 km option)~0-5 km~0-5 km~0-5 km
Power Requirement100-240 VAC, 50/60 Hz;
11-28 VDC, nominally 500 mA at 12 V;
6.0 watt
100-240 VAC, 50/60 Hz;
nominally 500 mA at 12 VDC;
6.0 watt
100-240 VAC, 50/60 Hz;
nominally 500 mA at 12 VDC;
6.0 watt
100-240 VAC, 50/60 Hz;
nominally 250 mA at 12 VDC;
3 watt
SizeStandard Case:
3.6×7.9×9.4 in
9x20x24 cm
OEM Version:
2.5x7x9 in
6.2×17.8×22.9 cm
Standard Case:
3.6×7.9×9.4 in
9x20x24 cm
OEM Version:
2.5x7x9 in
6.2×17.8×22.9 cm
Standard Case:
3.6×7.9×9.4 in
9x20x24 cm
OEM Version:
2.5x7x9 in
6.2×17.8×22.9 cm
Standard Case:
3.6×7.9×9.4 in
9x20x24 cm
OEM Version:
2.5x7x9 in
6.2×17.8×22.9 cm
WeightStandard Case:
4.2 lb
(1.9 kg)
OEM Version:
2.8 lb
(1.3 kg)
Standard Case:
3.9 lb
(1.8 kg)
OEM Version:
2.5 lb
(1.1 kg)
Standard Case:
3.9 lb
(1.8 kg)
OEM Version:
2.5 lb
(1.1 kg)
Standard Case:
4.8 lb
(2.2 kg)
OEM Version:
3.3 lb
(1.5 kg)
Data Logger Capacity32,736 lines32,736 lines32,736 lines32,736 lines
Analog Inputs for Internal Logging of Other Instruments,
0-2.5 V
NoNoNoNo
Serial Output, RS232YesYesYesYes
USB OutputYesYesYesYes
Flash Card OutputNoNoNoNo
Data Transfer Baud Rates2400, 4800, 192002400, 4800, 192002400, 4800, 192002400, 4800, 19200
Analog Voltage Output0-2.5 V0-2.5 V0-2.5 V0-2.5 V
Analog Current Output4-20 mA4-20 mA4-20 mA4-20 mA
Output RangesUser-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
User-Defined
Scaling Factor in Menu
DewLine™YesYesYesNo
Flow ThroughOptionOptionOptionYes
GPS OptionNoNoNoNo
Bluetooth OptionYesYesYesYes
Relay with 2 SetpointsYes (2)Yes (2)Yes (2)Yes (2)
Air Pump Lifetime (hours)15,00015,00015,000N/A